3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Repeat Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation.
REPAIR THE ACC FLOW SWITCH.
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.
SUBMIT AN ERN FOR THE REPLACEMENT OF THE CHLORINE PUMP.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Perimeter barrier had gaps greater than 4 inches.
Repair the perimeter barrier so that there are not any gaps greater than 4 inches anywhere along the barrier.
MODIFY THE FENCE TO LIMIT THE GAP BETWEEN THE GROUND AND THE BOTTOM OF THE FENCE.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 13-July-2023
Comments |
---|
Equipment requiring ODH plan approval has been replaced since the inventory report dated 6-18-20 without submitting an ERN to ODH. The Disinfection Chemical Feeder Stenner model # 45M5 was replaced with a Flex Flo model# A1N20A-4T. |