[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications. REPAIR THE VALVE ON THE AUTOMATIC CHEMICAL CONTROLLER TEST CELL SO YOU CAN TEST THE ACC FLOW SWITCH/PUMP INTERLOCK. YOUR RECORD SHEET INDICATES THAT THE ACC HAS BEEN TESTED DAILY. AFTER REPAIRING THE VALVE, TEST THE ACC USING THE TEST CELL VALVE.. Correct By: 06-Jun-2022
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. TIGHTEN HANDRAIL. Correct By: 10-Jun-2022
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
12 ft. non-telescopic reach pole with Shepherd's crook was not provided at the guarded pool.
Provide the non-telescopic reach pole at the pool at all times. PROVIDE A REACH POLE WITH A SHEPHERD'S CROOK. Correct By: 10-Jun-2022
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times. PROVIDE FIRST AID KIT. Correct By: 10-Jun-2022


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 03-June-2022


Comments
CHECK THE PRESSURE GAUGE ON TOP OF THE FILTER. IT WAS READING 52 PSI.
IT IS RECOMMENDED THAT THE CHLORINE LEVEL BE REDUCED TO BELOW 10 PPM.
DEPTH MARKING WILL NEED TO BE REPAINTED BEFORE NEXT YEAR.
HAVE THE BACKFLOW PREVENTER INSPECTED ANNUALLY.
THE BATHROOM HAND SINK SHOULD HAVE HOT WATER PER BUILDING CODE.
POOL WILL NEED TO BE PARTIALLY DRAINED NEXT MONTH TO AVOID CYA EXCEEDING MAXIMUM LEVELS OF 70 PPM.

When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm

Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals.

The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records reveal that the main drain suction outlet covers (Lawson Neptune Benson MLD-SG-1212) were installed on 5-1-21. The covers have a 10 year life span and must be replaced before 5-1-31.