[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Repeat Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. -Observed the free chlorine is not being recorded every day the pool is open or every 4 hours the pool is open as required. -Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours.

3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use. -Observed the combined chlorine is not being recorded every day the pool is open or every 4 hours the pool is open as required. -Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use.

3701-31-04 (B)(4)(a)(iii) / pH is tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Repeat pH was not tested daily at pool side and/or at required intervals for pools/automatic chemical controllers/special features. -Observed the pH is not being recorded every day the pool is open or every 4 hours the pool is open as required. -pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use.

3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Repeat Water temperatures were not being recorded daily. -Observed there are days the pool is not documented as being closed that the water temperture was not recorded. -Take and record the water temperature at least once/day.

3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Repeat Test kit reagents were not fresh or stored properly. -Observed reagents were expired. -Obtain fresh reagents.

3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool. -Observed the shepherd's hook had been removed from the reach pole. -Repair or replace the shepherd's hook.

3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working. -Observed the emergency phone does not work. -Ensure that the emergency device is functioning properly and rings to the emergency response authorities.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 15-December-2023


Comments
-Pool testing records are not being adequately kept.