3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Repeat Equipment/chemical/storage areas were not secured. Equipment room not locked.
These storage areas must be kept inaccessible to everyone but authorized personnel. Secure the areas.
KEEP EQUIPMENT ROOM LOCKED. Correct By: 07-Jun-2022
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Flow rate exceeds the maximum flow for the filters
All equipment must be maintained in accordance with the manufacturers specifications.
REDUCE THE FLOW RATE TO 196 GPM OR LESS. Correct By: 07-Jun-2022
3701-31-04 (B)(6)(n) / Proper pool operating water level is maintained
The operating water level of the pool was not maintained. Water level above the skimmer.
Increase the volume of the pool water until the pool operating water level is restored.
REDUCE WATER LEVEL TO THE MIDDLE OF THE SKIMMER OPENING SO THE SKIMMERS CAN FUNCTION PROPERLY. Correct By: 07-Jun-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 06-June-2022
Comments |
---|
When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. Our records show that the main drain suction outlet covers (Waterway 640-472xV) were installed 6/18/2018. The covers have a 7 year life span and must be replaced before 6/18/2025. The attendant was observed performing onsite chemical tests appropriately and ihe operator is aware of the acceptable parameters and necessary corrective actions. |