3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
Quat Disinfectant stored above the Alkalinity up bucket.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
DO NOT STORE LIQUID CHEMICALS ABOVE POWDERED OR DRY CHEMICALS. OPERATOR INDICATED THAT HE WOULD MOVE CHEMICALS. Correct By: 21-Mar-2022
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH).
Contact ODH to obtain approval for any construction/alterations before operating pool.
SUBMIT AN ERN TO ODH FOR THE REPLACEMENT OF THE PUMP. Old Pump Sta-Rite PE5D-181L .75 HP. New pump Pentair Intelliflo
REPORTEDLY, INSTALLER HAS SENT ODH THE ERN. Correct By: 28-Mar-2022
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS/APSOS/ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
TEST AND RECORD THE ACC FLOW SWITCH AND THE SVRS MONTHLY. RECORD ON THE WEEKLY LOG SHEET. OPERATOR INDICATED THAT HE TESTS ACC BUT HAS NOT RECORDED RESULTS. Correct By: 28-Mar-2022
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH Correct By: 11-Apr-2022
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY. Correct By: 04-Apr-2022
Facility Type: Spa
[?] Inspection Type: Follow-up
Inspection Date: 01-April-2022