3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat Outlet covers were not compliant covers. Covers have expired.
Do not operate the pool without compliant outlet covers. Install compliant outlet covers prior to placing the pool back into operation.
REPLACE THE MAIN DRAIN COVERS. KEEP THE CERTIFICATE OF COMPLIANCE (COC). RECORD THE DATE OF INSTALLATION ON THE COC.
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Equipment/chemical/storage areas had hazards present.
These storage areas must be kept free of hazards to avoid a serious public health nuisance.
KEEP LID ON THE CHEMICAL BUCKETS. Correct By: 09-Nov-2022
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.
SUBMIT EQUIPMENT REPLACEMENT NOTIFICATION FORM FOR THE REPLACEMENT OF THE PUMP.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING WEIR IN THE SKIMMER.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 09-November-2022
Comments |
---|
THE COMBINE CHLORINE IS BEING RECORDED WRONG. FREE CHLORINE PLUS COMBINE CHLORINE EQUALS TOTAL CHLORINE RECORD THE CHEMICALS THAT ARE ADDED BY HAND ON THE LOG SHEET. |