[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Corrected During Inspection Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation. FREE CHLORINE LEVEL WAS RAISED TO 1.4 AT THE TIME OF INSPECTION. Correct By: 13-Oct-2021

3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Weir missing in one skimmer
All equipment must be maintained in accordance with the manufacturers specifications. REPLACE MISSING WEIR IN SKIMMER. Correct By: 13-Oct-2021
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Ladders/stairs/steps were not in good repair or were not slip resistant. Ladder missing tread.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair. REPLACE THE MISSING TREAD ON THE LADDER STEPS.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. INCREASE ALK Correct By: 20-Oct-2021
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities. REPAIR EMERGENCY PHONE IN POOL AREA. Correct By: 20-Oct-2021


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 13-October-2021