[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The cover on the skimmer equalizer line outlet was not covered with a VGB approved cover.
COVER THE EQUALIZER LINE OUTLET WITH A VGB APPROVED COVER OR PLUG THE OUTLET AT THE WALL. Correct By: 14-Mar-2019

3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. INCREASE FLOW RATE TO AT LEAST 54 GPM BUT LESS THAN 98 GPM. Correct By: 14-Mar-2019
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. INCREASE ALKALINITY. Correct By: 02-Mar-2019


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 28-February-2019