[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Repeat Deck surfaces had standing water or other hazards.
Repair areas of the deck where standing water is occurring. REPAIR THE TOP OF THE WALL IN THE POOL TO ELIMINATE THE STANDING WATER.
3701-31-04(D)(6)(a)(1) / Combined chlorine shall not exceed 1.0 ppm.
Combined chlorine was greater than 1.0 ppm.
Treat the pool so that the combined chlorine is less than 1 ppm. ADJUST COMBINE CHLORINE LEVEL TO LESS THAN 1 PPM. REPAIR OF THE UV LIGHT WOULD HELP MAINTAIN PROPER COMBINE CHLORINE LEVELS.


Inspection Information


Facility Type: Special Use

[?] Inspection Type: Standard

Inspection Date: 20-February-2024


Comments
The Certificate of Compliance for the main drain covers is available in the equipment room. Our records show that the main drain suction outlet covers (Lawson MLD-FGD-1818) were installed 3/13/2020. The covers have a 10 year life span and must be replaced before 3/13/2030.

CHECK SCREWS IN THE MAIN DRAIN IN THE SHALLOW END OF THE POOL. INSTALL IMMEDIATELY IF ANY SCREWS ARE MISSING.