3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Lighting not sufficient in equipment room. Light not working
REPAIR LIGHTS IN THE EQUIPMENT ROOM. Correct By: 21-Aug-2021
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE FLOW RATE TO AT LEAST 69 GPM
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
Repeat A means of determining rate-of-flow was not found for all water pumps.
Properly install a flow meter or have a pump curve available for every water pump used for the pool.
INSTALL PRESSURE GAUGE AFTER WATERFALL PUMP FOR USE DETERMINING FLOW RATE.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 19-August-2021