3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical bag was stored on the floor in the equipment room
Properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
STORE THE BAG OF BICARB OFF OF THE FLOOR. Correct By: 09-Jun-2022
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Weirs missing in the skimmers.
All equipment must be maintained in accordance with the manufacturers specifications.
INSTALL WEIRS IN THE SKIMMERS. Correct By: 15-Jun-2022
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation. Pressure gauge on top of the filter appears not to be functioning.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR PRESSURE GAUGE ON TOP OF THE FILTER. Correct By: 15-Jun-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 08-June-2022
Comments |
---|
When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm. Safety Data Sheets (SDS) are kept in the lifeguard notebook. Keep Personal Protective Equipment (PPE), chemical gloves and goggles, are available for handling chemicals. The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records show that the main drain suction outlet covers (AquaStar WAV12) were installed 6/1/2019. The covers have a 5 year life span and must be replaced before 6/1/2024. The operator was observed performing onsite chemical tests appropriately and is aware of the acceptable parameters and necessary corrective actions. |