3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Repeat Corrected During Inspection Equipment/chemical/storage areas were not secured.
-Observed the lock on the spa equpiment area was not properly secured which allows the gate to be opened without unlocking it.
-After the inspection, the lock was placed correctly onto the gate by the inspector, thereby correcting the violation.
-ENSURE THE LOCK IS PROPERLY APPLIED, SO THE STORAGE AREA IS KEPT INACCESSIBLE TO EVERYONE BY AUTHORIZED PERSONNEL.
3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv.
-Observed the ORP to be 605.
Have the ACC unit inspected to determine why the ORP is low.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
-Observed the pH to be 7.0
-Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
-Observed the alkalinity to be 30ppm.
-Raise the total alkalinity to be at least 60ppm.
3701-31-04 (C)(8) / Spa water is drained at least every 30 days and is recorded
Repeat Spa water was not drained in the last 30 days.
-Observed the spa has not been recorded as being drained within the last 30 days. Last date it was recorded was 8/27/23.
-If the spa was drained but not recorded, record the date. If it has not been drained in the past 30 days, it is to be immediately drained.
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 23-October-2023
Comments |
---|
-NOTE THE REPEAT VIOLATIONS AND CORRECT ALL ASAP. -MAINTAIN POOL AND WATER CHEMISTRY PROPERLY TO ENSURE THESE REPEAT VIOLATIONS DO NOT KEEP OCCURRING. |