3701-31-04 (B)(1)(b) / SVRS device(s) shall be functional.
Critical The SVRS device that is being used as a secondary means to prevent entrapment/evisceration was not functional at the time of the inspection. SVRS NOT WORKING FOR THE JET PUMP.
Do not operate the pool when the SVRS is not functioning. Ensure the SVRS is operating properly prior to placing the pool back into operation.
REPAIR THE JET PUMP SVRS. Correct By: 27-Sep-2023
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.
APPROVAL FOR THE PUMP REPLACEMENT HAS NOT BE GIVEN BY ODH. CONTACT ODH FOR EXPLANATION AS TO WHY APPROVAL HAS NOT BEEN GIVEN.
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS test results/ service records were not maintained.
The test results for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results.
TEST AND RECORD THE SVRS.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH. Correct By: 29-Sep-2023
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY. Correct By: 29-Sep-2023
3701-31-04 (C)(7) / Spa water temperature is less than 104 degrees Fahrenheit/ thermometer is provided
Spa water temperature was greater than 104 degrees Fahrenheit.
Do not operate the spa at a water temperature greater than 104 degrees Fahrenheit. Reduce the water temperature to 104 degrees or less.
ADJUST WATER TEMPERATURE. Correct By: 04-Oct-2023
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 27-September-2023
Comments |
---|
KEEP THE CERTIFICATE OF COMPLIANCE FOR THE MAIN DRAINS AND FILL IN THE DATE OF INSTALLATION. |