[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical The free chlorine level was .6 ppm.
This is a critical violation and poses an imminent health hazard. THE POOL MUST IMMEDIATELY CLOSE UNTIL THE FREE CHLORINE LEVEL IS AT LEAST 1 PPM AND THE HEALTH DEPARTMENT VERIFIES COMPLIANCE. Call me at 440-219-7158 when pool is in compliance. Correct By: 18-Jun-2020
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemicals not stored properly.
INCREASE THE VENTILATION IN THE EQUIPMENT ROOM TO REDUCE THE ROOM TEMPERATURE. Correct By: 24-Jun-2020
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Corrected During Inspection Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly. TEST ACC MONTHLY

3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH).
Contact ODH to obtain approval for any construction/alterations before operating pool. SUBMIT AN EQUIPMENT REPLACEMENT NOTIFICATION TO THE OHIO DEPARTMENT OF HEALTH FOR THE REPLACEMENT OF THE DISINFECTION UNIT. FLEX FLO A1N10A-7T WAS REPLACED WITH A FLEX FLO A1N30A-T7. Correct By: 24-Jun-2020
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
Repeat Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely. PROVIDE AN AIR GAP ON THE FILTER DISCHARGE LINE. Correct By: 24-Jun-2020
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation. REPAIR THE FLOW METER. Correct By: 24-Jun-2020
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated. REPAINT THE DEPTH MARKING AND NO DIVING SIGNS Correct By: 24-Jun-2020
3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Test kit reagents were not fresh or stored properly.
STORE THE TEST KIT IN ROOM AT 85 DEGREES OR LESS. Correct By: 19-Jun-2020


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 18-June-2020


Comments
Keep the chemicals’ Safety Data Sheets (MSDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals.

The Certificate of Compliance was not available for the main drain cover. One was supplied to operator at the time of inspection. Keep a copy at the facility for future review.