[?] A summary of the violations found during the inspection are listed below.

No critical violations were documented at the time of inspection.

No violations were documented at the time of inspection.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 24-July-2013


Comments
*Pool alkalinity (46) is lower than the required minimum of 60ppm. Add approximately 1 pound sodium bicarbonate to elevate alkalinity to the 70-80ppm range.

*Pool cyanuric acid (84ppm) is above the required 70 ppm or less. Dilution is the only way to remove cyanuric acid. If 1/2 the volume of the pool is emptied, then cyanuric acid levels should fall into the 40ppm range.

*Pool Free and Total Chlorine were to high to read by my digital test kit with a range of 10+ppm for detection range. There is no set high level range indicated in code for chlorine, however it would be more desirable to be in the 3-5ppm range to avoid irritating sensitive bathers skin, especially young children that frequent this pool.