3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical Record of SVRS test was not on the weekly operational log sheet.
TEST AND RECORD THE SVRS BEFORE OPENING FOR THE SEASON AND AT LEAST ONCE A MONTH. Correct By: 22-Jun-2020
3701-31-04 (B) / All facilities are maintained clean, safe and sanitary condition and in good repair.
The facilities were not maintained in a safe, clean & sanitary, and in good repair. Per management company, bathrooms are locked because of plumbing issues.
REPAIR THE PLUMBING IN THE BATHROOMS AND MAKE THEM AVAILABLE FOR USE. Correct By: 22-Jun-2020
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Hand rail is loose at the shallow end.
All equipment must be maintained in accordance with the manufacturers specifications.
TIGHTEN OR REPAIR THE HANDRAIL AT THE SHALLOW END. Correct By: 22-Jun-2020
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The gate does not close and latch consistently.
TIGHTEN THE SPRING ON THE GATE OR OTHERWISE REPAIR THE GATE SO THAT IT CLOSES AND LATCHES CONSISTENTLY. Correct By: 22-Jun-2020
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST THE pH. Correct By: 22-Jun-2020
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 19-June-2020