3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
LABEL THE CHLORINE TANK Correct By: 08-Jun-2019
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The flow rate exceeds the flow rating of the drain covers. Drain cover covers are rated at 125 gpm.
All equipment must be maintained in accordance with the manufacturers specifications.
REDUCE THE FLOW RATE TO 125 GPM OR REPLACE THE DRAIN COVERS WITH ONES WITH A HIGHER FLOW RATE. Correct By: 08-Jun-2019
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
Repeat Backwash lines and lines from drainage sumps did not have an air gap prior to discharge.
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
SHORTEN THE FILTER BACKWASH PIPE SO IT IS ABOVE THE FLOOD RIM OF THE STAND PIPE. Correct By: 08-Jun-2019
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat Ladders/stairs/steps were not in good repair or were not slip resistant.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHTEN THE HAND RAIL (THAT IS CLOSEST TO THE GATE). Correct By: 08-Jun-2019
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The gate does not self-close.
ADJUST THE GATE SPRING SO THAT THE GATE CLOSES ON ITS OWN. Correct By: 14-Jun-2019
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 07-June-2019
Comments |
---|
Our records have been updated to show: The main drain suction outlet cover (Hayward WG1048E) was installed on 5-23-19. The cover has a 7 year life span and must be replaced before 5-23-26. -date mark the log sheets |