[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low. INCREASE ORP TO AT LEAST 650 MV Correct By: 03-Jun-2022
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS/APSOS/ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. TEST AND RECORD ACC AT LEAST MONTHLY. Correct By: 03-Jun-2022
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. INCREASE FLOW RATE TO AT LEAST 115 GPM BUT LESS THAN 170 GPM. Correct By: 03-Jun-2022
3701-31-04 (E)(2)(b)(i) / 12 ft. non-telescopic reach pole with Sheppard's crook & a USCG Type IV personal flotation device with 30 - 60 foot throw line.
12 ft. non-telescopic reach pole with Shepherd's crook was not provided at the guarded pool. Reach pole is telescopic.
Provide the non-telescopic reach pole. MAKE REACH POLE NON-TELESCOPIC. A SCREW CAN BE DRILLED INTO THE POLE TO MADE IT FIXED IN PLACE AND NON-TELESCOPIC. Correct By: 03-Jun-2022


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 27-May-2022


Comments
The spine board was dirty. SPINE BOARD CLEANING RECOMMENDED.
Restrooms do not have hot water. HOT WATER FOR SINKS IN RESTROOM RECOMMENDED.
I did not see sign stating "Swimming alone is not recommended". IF NOT ALREADY POSTED, POST SIGN STATING "SWIMMING ALONE IS NOT RECOMMENDED"

Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals.

The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our records show that the main drain suction outlet covers (AquaStar 10ARCFR) were installed on 5-23-19. The covers have a 5 year life span and must be replaced before 5-23-24. These drain covers have a maximum flow rating is 170 gpm. When replacing the covers, ensure that the new covers' flow rating will not be exceeded. 180 gpm.

When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm