[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat The equalizer outlet on the pool wall is not plugged or covered with a VGB approved cover.
INSTALL VGB COMPLIANT COVERS OVER THE EQUALIZER OUTLETS OR PLUG THE OUTLETS AT THE POOL WALL.
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical The free chlorine level was below 1 ppm.
INCREASE THE FREE CHLORINE LEVEL TO AT LEAST 1 PPM BEFORE REOPENING. THE POOL WAS CLOSED AT THE TIME OF INSPECTION.

3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
The licensee /authorized representative was not keeping or maintaining operational records correctly.
TEST FOR FREE, COMBINE, AND TOTAL CHLORINE. TEST FOR ALKALINITY WEEKLY. TEST AND RECORD THE SVRS MONTHLY. Correct By: 25-Sep-2018


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 24-September-2018


Comments
Correction made since the 5-7-18 inspection
-water testing and recording keeping is done every 4 hours.