3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical The test of the SVRS (Emotron) was not recorded.
TEST AND RECORD THE FUNCTION OF THE SVRS. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical containers were stored without labels identifying the contents. The chlorine tank was not labeled.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
LABEL THE CHLORINE TANK. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Cross connection hazards were present. The hose bib in the filter room is not back flow protected.
Remove all cross connection hazards from the pool area.
INSTALL AN ASSE 1011 BACK FLOW PREVENTER ON THE HOSE BIB IN THE FILTER ROOM. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meter was not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR THE FLOW METER. Correct By: 30-Jun-2018
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Depth markers/deck warning signs were not maintained in a clearly legible/visible manner. Tow of the "NO DIVING" signs were missing.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated.
REPLACE THE MISSING "NO DIVING" SIGNS ON THE DECK. Correct By: 30-Jun-2018
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool. The rope was missing from the ring.
Provide a proper floatation device at all times.
ATTACH A 30-60 FT ROPE ONTO THE RING BUOY. Correct By: 30-Jun-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 21-June-2018