3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical (REPEAT) Outlet covers were not compliant covers. Covers expired.
Do not operate the pool without compliant outlet covers. Install compliant outlet covers prior to placing the pool back into operation.
REPLACE THE MAIN DRAIN COVERS.
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.SUBMIT EQUIPMENT REPLACEMENT NOTIFICATION FORM FOR THE REPLACEMENT OF THE PUMP.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
(REPEAT) Equipment was not maintained per manufacturers specifications. Skimmer weir missing.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE MISSING WEIR IN THE SKIMMER.
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
REPLACE RUSTY SCREWS ON THE LADDER. Correct By: 15-Sep-2022
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A USCG Type IV personal flotation device with 30 -60 foot throw line was tangled.
Provide a proper floatation device at all times ready to use.
UNTANGLE THE ROPE ON THE RING BUOY. Correct By: 08-Sep-2022
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided. Kit almost empty.
Provide first aid equipment, including a first aid kit, at the pool at all times.
REPLACE FIRST AID KIT SUPPLIES. Correct By: 08-Sep-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 01-September-2022