3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INREASE THE FLOW RATE TO AT LEAST 106 GPM BUT LESS THAN 123 GPM
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Repeat Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
REPAIR THE EMEERGENCY PHONE AND POST A SIGN STATING EMERGENCY PHONE ON THE BOX
3701-31-04 (E)(3)(d) / "WARNING or DANGER - POOL CLOSED" sign(s) posted-when the pool is closed
Repeat The pool was closed but the "WARNING or DANGER - POOL CLOSED" sign(s) were not posted.
Post the "WARNING or DANGER - POOL CLOSED" sign at all times the pool is not available for use.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 14-August-2018
Comments |
---|
POOL CLOSED AT THE TIME OF INSPECTION "WATER TESTING AND RECORD KEEPING", "CRITICAL OPERATIONAL ITEMS", AND CDC FECAL ACCIDENT RESPONSE HANDOUTS WERE SUPPLIED TO THE OPERATOR AND REVIEWED TO ENSURE THAT THE OPERATOR IS KNOWLEDGEABLE OF THE REQUIRED CHEMISTRY LEVELS, CRITICAL ITEMS WHERE THE POOL MUST CLOSE, AND HOW TO RESPOND TO A FECAL ACCIDENT. THE OPERATOR SEEMED AWARE OF THESE ITEMS. |