3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.
SUBMIT AN EQUIPMENT REPLACEMENT NOTIFICATION TO THE OHIO DEPARTMENT OF HEALTH FOR THE REPLACEMENT OF THE SPA JET PUMP. OLD PUMP PENTAIR WHISPERFLO XFK-12, NEW PUMP PENTAIR WHISPERFLO XFK-20. Correct By: 23-Feb-2024
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Equipment, at a public swimming pool, was changed/altered without obtaining approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN).
Obtain approval from the Ohio Department of Health (ODH) by submitting an Equipment Replacement Notification (ERN) before operating pool.
SUBMIT AN EQUIPMENT REPLACEMENT NOTIFICATION TO THE OHIO DEPARTMENT OF HEALTH FOR THE REPLACEMENT OF THE DISINFECTION CHEMICAL FEEDER. OLD FEEDER STENNER 45M5, NEW STENNER 85M5. Correct By: 23-Feb-2024
3701-31-04(D)(6)(a)(1) / Combined chlorine shall not exceed 1.0 ppm.
Repeat Combined chlorine was greater than 1.0 ppm.
Treat the pool so that the combined chlorine is less than 1 ppm.
ADJUST COMBINED CHLORINE TO LESS THAN 1 PPM. Correct By: 25-Feb-2024
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 16-February-2024
Comments |
---|
Safety Data Sheets (SDS) are kept in the equipment room and Personal Protective Equipment (PPE), chemical gloves and goggles, are available for handling chemicals. The Certificate of Compliance for the main drain covers is available in the equipment room. -Our record show that the main drain suction outlet covers (AquaStar WAV9 x 8) were installed 1/24/2020. The covers have a 5 year life span and must be replaced before 1/24/2025. New pump curve will be needed to accommodate the new jet pump. |