3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The equalizer lines at the pool wall are not covered with a compliant cover and are not plugged.
PLUG THE EQUALIZER SUCTION OUTLET AT THE POOL WALL OR INSTALL A VGB COMPLIANT COVER. Correct By: 07-Jul-2017
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week.
TEST AND RECORD CYANURIC ACID WEEKLY AND ALKALINITY WEEKLY. Correct By: 14-Jun-2017
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices shall be maintained.
Backflow prevention devices were not maintained to function properly. The hose bib in the filter room is not back flow protected.
Have the backflow prevention device evaluated or replaced so that backflow is prevented.
INSTALL A ASSE 1011 BACKFLOW PREVENTER ON THE HOSE BIB IN THE FILTER ROOM. Correct By: 07-Jul-2017
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
Backwash lines and lines from drainage sumps did not have an air gap prior to discharge. The filter backwash pipe does not have an air gap.
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
PROVIDE AN AIR GAP FOR THE FILTER BACKWASH PIPE. Correct By: 07-Jul-2017
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
A means of determining rate-of-flow was not found for all water pumps. The flow meter is improperly installed. It is 9 inches downstream from an elbow of a 2 in pipe.
Properly install a flow meter or have a pump curve available for every water pump used for the pool.
RELOCATE THE FLOW METER SO IT IS AT LEAST 10 TIMES THE DIAMETER OF THE PIPE FROM THE NEAREST TURBULENCE DOWNSTREAM AND AT LEAST 5 TIMES THE DIAMETER OF THE PIPE UPSTREAM FROM A TURBULENCE. Correct By: 07-Jul-2017
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. The hand rail to the steps is loose.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHT THE HANDRAIL FOR THE STEPS. Correct By: 07-Jul-2017
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Depth markers/deck warning signs were not maintained in a clearly legible/visible manner. The "No Diving" markings are more than 25 ft apart at one end.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated.
PROVIDE AN ADDITIONAL "NO DIVING " SIGN TO ENSURE THAT THEY ARE NOT MORE THAN 25 FT APART. Correct By: 07-Jul-2017
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool. The reach pole with the shepherds crook is 9 ft long.
Provide a 12 ft. non-telescopic reach pole in the pool area at all times.
PROVIDE A 12 FT LONG POLE WITH A SHEPHERD'S CROOK. Correct By: 07-Jul-2017
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 07-June-2017
Comments |
---|
IT APPEARS THAT NEW DRAIN COVERS WERE INSTALLED THIS SEASON. PLEASE MAKE A COPY OF THE CERTIFICATE OF COMPLIANCE AND THE INSTALLATION INSTRUCTIONS AND PROVIDE TO THE HEALTH DEPARTMENT. ALSO COMPLETE THE CERTIFICATE OF INSTALLATION AND MAKE A COPY FOR THE HD. CHEMICALS SHOULD NOT BE PLACED IN THE SKIMMER BASKETS. REMOVE THE CHLORINE PUCKS, A FIT AID KIT MUST BE MADE AVAILABLE. IF THE KIT IS KEPT AT THE FRONT DESK, PLACE A SIGN AT THE POOLS STATING THAT. RULES WILL BE CHANGING TO REQUIRE AN EMERGENCY PHONE THAT DIALS DIRECTLY OUT (NOT TO THE FRONT DESK). A SIGN SHOULD STATE THAT THE EMERGENCY PHONE IS AT THE FRONT DESK AND EMERGENCY NUMBERS SHOULD BE POSTED AT THE FRONT DESK PHONE. POOL WAS PAINTED WITH COLOR OCEAN BLUE HE-402. TINT ADDED BY COMPANY 419-626-2461. |