3701-31-04 (B)(5) / Records are maintained for at least two years
Readings were not being recorded and read every 4 hours.
Maintain all records and have them available upon request.
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
Flowmeter was not operating.
Properly install a flow meter or have a pump curve available for every water pump used for the pool.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
3701-31-04 (D)(5) / Cyanuric acid level does not exceed 70 ppm
Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 24-June-2014