3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The filter has a maximum allowable flow rate (printed on the fitter data plate) of 48 gpm which is being exceeded.
All equipment must be maintained in accordance with the manufacturers specifications.
REDUCE THE FLOW RATE TO 48 GPM OR LESS BUT AT LEAST 32 GPM. Correct By: 09-Nov-2022
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
(REPEAT) Cross connection hazards were present
Remove all cross connection hazards from the pool area.
INSTALL AN ASSE 1011 VACUUM BREAKER ON THE HOSE BIB IN THE EQUIPMENT ROOM (UNDER THE EYE WASH STATION).
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Equipment/chemical/storage areas had hazards present. Aqua Balance liquid chemical is stored over dry chemicals.
These storage areas must be kept free of hazards to avoid a serious public health nuisance.
MOVE THE AQUA BALANCE LIQUID CHEMICAL FROM OVER OTHER CHEMICALS. Correct By: 08-Nov-2022
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Flow or pressure switch for a shut off valve was not tested monthly
Provide records indicating that the unit is being tested monthly.
TEST AND RECORD ACC FUNCTION MONTHLY. Correct By: 10-Nov-2022
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
The test kit provided was not in good repair. Alkalinity reagents are expired.
Maintain the test kit in good repair to conduct water quality tests.
REPLACE THE EXPIRED REAGENTS. Correct By: 14-Nov-2022
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not adequately supplied.
Provide first aid equipment, including a first aid kit, at the pool at all times.
RESTOCK THE FIRST AID KIT WITH BANDAGES OR REPLACE THE KIT. Correct By: 14-Nov-2022
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
REPAIR THE EMERGENCY PHONE. Correct By: 10-Nov-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 08-November-2022
Comments |
---|
READ THE FLOW METER FROM THE LEFT SIDE (UNDER SCH 40). THE RIGHT SIDE IS FOR FLOW METERS INSTALLED ON A SCH 80 PIPE (THINNER WALED PIPE). TEST AND RECORD WATER RESULTS DAILY, OR IF THE POOL IS CLOSED, RECORD "POOL CLOSED" |