3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical The main drain suction outlet covers were installed at an unknown date. No information was available at the time of inspection.
IF THE AGE OF THE MAIN DRAIN COVERS ARE UNKNOWN OR IF THEY HAVE BEEN IN PLACE FOR 7 YEARS OR LONGER THEY MUST BE REPLACED. WHEN REPLACING THE DRAIN COVERS RETAIN THE CERTIFICATE OF COMPLIANCE, THE INSTALLATION INSTRUCTIONS AND COMPLETE AND RETAIN THE CERTIFICATE OF INSTALLATION. Correct By: 15-May-2019
3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation.
REPAIR THE FLOW SWITCH ON THE ACC. Correct By: 07-Jun-2018
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. The skimmer boxes were missing the weirs.
All equipment must be maintained in accordance with the manufacturers specifications.
INSTALL WEIRS IN THE SKIMMER BOXES. Correct By: 27-Jun-2018
3701-31-04 (B)(6)(c)(i) / Backflow prevention devices are maintained
Backflow prevention devices were not tested.
Have the backflow prevention device evaluated or replaced so that backflow is prevented.
HAVE THE BACKFLOW PREVENTER INSPECTED. Correct By: 27-Jun-2018
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps have an air gap and are open to freely drain
Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
PROVIDE AN AIR GAP BETWEEN THE BOTTOM OF THE FILTER BACKWASH DRAIN AND THE TOP OF THE FLOOR DRAIN. Correct By: 27-Jun-2018
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR/REPLACE THE FLOW METER. Correct By: 27-Jun-2018
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant. The hand rail was loose.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHTEN THE HAND RAILS. Correct By: 27-Jun-2018
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Chemical containers were stored without labels identifying the contents. The shock was stored on top of the liquid chemicals.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
DO NOT STORE DIFFERENT TYPES OF CHEMICALS OF TOP OF EACH OTHER.
LABEL THE CHEMICAL TANKS Correct By: 27-Jun-2018
3701-31-04 (E)(2)(a)(ii) / A USCG Type IV personal flotation device with 30 -60 foot throw line provided
A USCG Type IV personal flotation device with 30 -60 foot throw line was not provided at the unguarded pool.
Provide a proper floatation device at all times.
OBTAIN A RING BUOY AND ATTACHED A 30-60 FT ROPE. Correct By: 27-Jun-2018
3701-31-04 (E)(3)(c) / Location of emergency telephone posted when the phone is not visible.
Sign indicating the location of the emergency device (telephone) was not provided and emergency device was not visible in the pool area.
Ensure that a sign informing patrons of the location of the emergency device is always visible in the pool area.
POST A LARGE SIGN INDICATING THE LOCATION OF THE EMERGENCY PHONE. Correct By: 27-Jun-2018
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 06-June-2018
Comments |
---|
The Health Department received a complaint that stated that there was garage in the pool and nothing was done about it. This inspection revealed that no garbage was in the pool. There was some dirt at the bottom of the pool but there were cleaning the poo at the time of inspection. |