3701-31-04 (B)(6)(b) / Replacement pipe is rigid PVC or the equivalent
Repeat Replacement pipe was not rigid PVC or equivalent. A rubber coupling is used before the pump.
Replace the non rigid PVC pipe with the proper rigid PVC pipe for public swimming pools.
REPLACE THE RUBBER COUPLING WITH APPROVED RIGID PIPE. Correct By: 02-Oct-2017
3701-31-04 (B)(6)(c)(ii) / Backwash lines and lines from drainage sumps shall have an air gap and remain open to freely drain.
Repeat Backwash lines and lines from drainage sumps did not have an air gap prior to discharge
Open the lines that discharge into the backwash or drainage sumps so that there is an air gap and the lines can drain freely.
PROVIDE AN AIR GAP ON THE BACKWASH LINE. Correct By: 02-Oct-2017
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 05-October-2017
Comments |
---|
Re-inspection only to check the filter room door. It is locked. |