3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Outlet covers were not compliant covers. Covers have expired
Do not operate the pool without compliant outlet covers. Install compliant outlet covers prior to placing the pool back into operation.
REPLACE MAIN DRAIN COVERS. KEEP AND POST A COPY OF THE CERTIFICATE OF COMPLIANCE. RECORD THE DATE OF INSTALLATION. Correct By: 21-Jan-2022
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week.
TEST AND RECORD ALKALINITY WEEKLY. Correct By: 28-Jan-2022
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Light burned out in the pool
All equipment must be maintained in accordance with the manufacturers specifications.
REPAIR LIGHT IN THE POOL. Correct By: 28-Jan-2022
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Weir missing in skimmer
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE WEIR (FLATTER) IN THE SKIMMER. Correct By: 28-Jan-2022
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE FLOW RATE TO AT LEAST 27 GPM Correct By: 28-Jan-2022
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Flow or pressure switch for a shut off valve was not tested monthly
Provide records indicating that the unit is being tested monthly.
ACC AND RECORD ACC FUNCTION MONTHLY. Correct By: 28-Jan-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 21-January-2022