3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
ORP reading was below 650 mv
Have the ACC unit inspected to determined why the ORP is low.
THE PROBES MAY NEED TO BE CLEANED AND THE ACC MAY NEED TO BE RECALIBRATED. Correct By: 28-Jun-2021
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE THE FLOW RATE TO AT LEAST 69 GPM. A NEW PUMP MAY BE NEEDED. Correct By: 28-Jun-2021
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
A means of determining rate-of-flow was not found for all water pumps. The pressure gauge is missing after the pump
Properly install a flow meter or have a pump curve available for every water pump used for the pool.
RE-INSTALL THE PRESSURE GAUGE AFTER THE PUMP FOR THE WATERFALL PUMP SO THE FLOW RATE CAN BE DETERMINED. Correct By: 28-Jun-2021
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
LOWER THE CYANURIC ACID LEVEL TO BELOW 70 PPM. Correct By: 28-Jun-2021
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool.
Provide a 12 ft. non-telescopic reach pole in the pool area at all times.
PLACE A SHEPHERD'S CROOK ON THE 12 FT REACH POLE AND KEEP THE REACH POLE IN THE POOL AREA. Correct By: 28-Jun-2021
3701-31-04 (E)(2)(d) / First aid kit provided
Corrected During Inspection First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
KEEP THE FIRST AID KIT IN THE POOL AREA SO IT IS AVAILABLE TO SWIMMERS. Correct By: 21-Jun-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 21-June-2021