3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Chlorine disinfectant residual was less than 1 ppm for the pool
Do not operate the pool when the disinfectant residuals are less than what is required. Ensure the chlorine disinfectant residual is at 1 ppm or above prior to placing the pool back into operation.
THIS IS A CRITICAL OPERATIONAL ITEM AND POSED AN IMMINENT HEALTH HAZARD. KEEP POOL CLOSED UNTIL CORRECTED. CALL LCPH AT 44-219-7158 WHEN CORRECTED. Correct By: 23-Jun-2021
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Weirs are missing in the skimmers.
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE THE MISSING WEIRS IN THE SKIMMERS. Correct By: 14-Jul-2021
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored improperly.
Properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
MOVE THE ALGICIDE FROM ABOVE THE CHLORINE CONTAINER. MOVE THE GLASS CLEANER FROM ABOVE THE ALKALINITY UP CONTAINER. Correct By: 24-Jun-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 23-June-2021
Comments |
---|
The Certificate of Compliance for the main drain cover is available in the equipment room. Our records show that the main drain suction outlet covers (AquaStar 1216) were installed 7/1/2018. The covers have a 7 year life span and must be replaced before 7/1/2025. |