[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. Some of the weirs in the skimmers are sticking in one postilion.
All equipment must be maintained in accordance with the manufacturers specifications. TRIM THE WEIRS SO THAT THEY FLOAT FREELY IN THE SKIMMER BOX. Correct By: 29-Jul-2021
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable. THE DOOR FROM THE LOCKER ROOM MUST BE SELF-LATCHING AND HAVE THE ACTUATING DEVICE AT LEAST 38 INCHES ABOVE THE GROUND. Correct By: 27-Jul-2021
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities. REPAIR EMERGENCY PHONE. Correct By: 29-Jul-2021


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 27-July-2021