3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications.
All equipment must be maintained in accordance with the manufacturers specifications.
CALIBRATE THE AUTOMATIC CHEMICAL CONTROLLER pH. Correct By: 18-Jun-2020
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Gaps under the perimeter fence more 7 inches from the bottom of the fence and the ground.
ADJUST THE FENCE OR ALTER THE GROUND/FENCE TO LIMIT THE GAP UNDER THE FENCE TO 4 INCHES. Correct By: 24-Jun-2020
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical The equipment room is cluttered, lacking space.
REMOVE BLUE TRASH CONTAINERS FROM THE EQUIPMENT ROOM TO PROVIDE ADEQUATE SPACE. Correct By: 24-Jun-2020
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH. Correct By: 19-Jun-2020
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 18-June-2020
Comments |
---|
Keep the chemicals’ Safety Data Sheets (MSDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. The Certificate of Compliance was not available for the main drain cover. One was supplied to operator at the time of inspection. Keep a copy at the facility for future review. The "NO DIVING" deck markings are only 3 inches in size. "Depth markings must be at least 4 inches. Underwater lights did not work. No after dark use of pool is permitted without light enough to clearly see the bottom of the pool. Hang up the emergency phone sign so it can be seen more easily. |