3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Skimmer missing a weir
All equipment must be maintained in accordance with the manufacturers specifications.
REPLACE MISSING WEIR IN SKIMMER
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
Repeat A means of determining rate-of-flow was not found for all water pumps.
Properly install a flow meter or have a pump curve available for every water pump used for the pool.
INSTALL A PRESSURE AND VACUUM GAUGE BEFORE AND AFTER THE JET PUMP OR INSTALL A FLOW METER WITH THE ADDITIONAL LENGTH OF PIPE FOR THE SPA JET PUMP
DISPLAY THE FORMULA FOR CALCULATING THE FLOW RATE
Calculation sheet was supplied during inspection
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 08-November-2019