[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. pH was 8.0
Treat the pool water so that the pH is within the acceptable range. LOWER THE pH TO BETWEEN 7.2 AND 7.8. Correct By: 18-Jan-2018
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities. REPAIR THE PHONE. POST THE EMERGENCY NUMBER (911) BY THE PHONE. OR IF THE EMERGENCY PHONE IS AT THE FRONT DESK, POST A SIGN IN THE POOL AREA WITH THE LOCATION OF THE EMERGENCY PHONE. Correct By: 18-Jan-2018


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 16-January-2018

Comments
Corrections that have been made since the 10-5-17 inspection.
-an air gap is on the filter backwash discharge line.
-all pipe is ridge ASTM 1875 pipe. No rubber coupling present.

THE EQUALIZER OUTLETS ON THE POOL WALL ARE NOT PLUGGED AND DO NOT HAVE A COMPLIANT COVER. THE EQUALIZER LINE IS PLUGGED INSIDE THE SKIMMER BOX. THE SUCTION ENTRAPMENT HAZARD HAS BEEN ELIMINATED, BUT THE PHYSICAL ENTRAPMENT HAZARD STILL EXISTS. THE EXISTING COVERS ON THE POOL WALL SHOULD BE REPLACED WITH PLUGS.