3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
- Observed the flow measure reading was below the minimum amount for the system.
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Flow or pressure switch for a shut off valve was not provided or the unit was not tested monthly
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly.
- Observed there is no flow switch for the indoor pool. Correct By: 17-Apr-2024
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 10-April-2024
Comments |
---|
-CDC DOES NOT RECOMMEND CHLORINE LEVELS HIGHER THAN 10 ppm. - Did not observe a flow switch for the indoor pool. Contact after this has been fixed for a re-inspection. - Flow measure reading was below the minimum required flow rate. |