3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical There is zero disinfectant in the pool.
This violation is a critical operational item and poses an imminent health hazard.
THE POOL MUST CLOSE UNTIL THE VIOLATION IS CORRECTED.
3701-31-04 (B)(1)(d) / Circulation/Disinfection system shall operate properly.
Critical The pump was not running.
This violation is a critical operational item and poses an imminent health hazard.
THE POOL MUST CLOSE UNTIL THE VIOLATION IS CORRECTED.
3701-31-04 (B)(1)(g) / Water clarity shall be sufficient to see the pool bottom (or Secchi disc).
Critical Water clarity was not sufficient to see the pool bottom (or Secchi disc)
Do not operate the pool when water clarity is poor. This violation is a critical operational item and poses an imminent health hazard.
CLOSE POOL UNTIL CORRECTED.
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week.
TEST AND RECORD CYA WEEKLY. Correct By: 07-Aug-2019
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
STORE THE BOX OF CHEMICALS OFF OF THE FLOOR. Correct By: 07-Aug-2019
3701-31-04 (D)(05) / Cyanuric acid level shall not exceed 70 ppm.
Repeat Cyanuric acid level exceeded 70 ppm
Drain the pool at least halfway and fill with clean water. Monitor the amount of cyanuric acid being used and adjust accordingly.
LOWER THE CYA Correct By: 07-Aug-2019
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 05-August-2019
Comments |
---|
When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm |