[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Outlet covers were not compliant covers. The skimmer equalizer outlets pose a limb entrapment hazard.
Do not operate the pool without compliant outlet covers. Install compliant outlet covers prior to placing the pool back into operation. INSTALL VGB COMPLIANT COVERS OVER THE SKIMMER EQUALIZER OUTLETS OR PLUG THE OUTLET AT THE POOL WALL TO ELIMINATE THE LIMB ENTRAPMENT HAZARD. Correct By: 03-Jul-2021
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Corrected During Inspection Cross connection hazards were present. The hose bib on the outside of the equipment room did not have a backflow preventer.
Remove all cross connection hazards from the pool area. PLACE AN ASSE 1011 BACKFLOW PREVENTER ON THE HOSE BIB. Correct By: 01-Jul-2021
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gates actuating devise less than 38 inches from ground..
Relocate the gate actuating devise at least 38 inches from ground level. PLACE THE GATE OPENER SO THE PULL KNOB IS AT LEAST 38 INCHES ABOVE THE GROUND. Correct By: 03-Jul-2021
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Corrected During Inspection Equipment/chemical/storage areas were not secured. Equipment room not locked.
These storage areas must be kept inaccessible to everyone but authorized personnel. Secure the areas. KEEP EQUIPMENT ROOM LOCKED. Correct By: 01-Jul-2021


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 01-July-2021

Comments
The operator was observed performing onsite chemical tests appropriately

The Certificate of Compliance for the main drain cover is available in the equipment room.

Our records show that the main drain suction outlet covesr (Waterway 640-472xV) were installed on 5/22/2019. The covers have a 7 year life span and must be replaced before 5/22/2026.