3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored without labels identifying the contents.
-Observed the large container of chlorine that is stored outside near the pump is still unlabeled.
PROMPTLY LABEL ALL CHEMICALS.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Repeat Test kit reagents were not fresh or stored properly.
-Observed the DPD reagent #2 was expired.
REPLACE EXPIRED REAGENTS WITH FRESH REAGENTS.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 01-August-2023
Comments |
---|
Observed the bag of chemicals that was stored on the floor in the equipment room had been relocated since the last inspection. When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm. This corrected alkalinity reading is to be documented on the reports when using cyanuric acid. NOTE THE REPEAT VIOLATIONS. PROMPTLY ADDRESS AND CORRECT THESE ISSUES. With no documentation on the installation date for the floor drains, they will need to be replaced. Keep certificates of compliance with installation dates on file for review. |