3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST THE pH Correct By: 21-Apr-2022
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
ADJUST ALKALINITY. Correct By: 21-Apr-2022
Facility Type: Spa
[?] Inspection Type: Standard
Inspection Date: 18-April-2022
Comments |
---|
THE MINIMUM FREE CHLORINE LEVEL IS 2 PPM. BELOW 2 PPM THE SPA MUST BE CLOSED. IT IS RECOMMENDED THAT THE FREE CHLORINE LEVEL BE SET SAFELY ABOVE 2 PPM. THAT WAY AN UNEXPECTED DROP IN LEVEL WILL NOT BRING IT BELOW 2 PPM WHICH REQUIRES CLOSURE OF THE SPA. The Certificate of Compliance for the main drain cover is available in the equipment room. Our records show that the main drain suction outlet covers (Lawson MLD-SG-1212) were installed 3/23/2016. The covers have a 10 year life span and must be replaced before 3/23/2026. |