[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Skimmer weirs missing.
All equipment must be maintained in accordance with the manufacturers specifications. REPLACE MISSING WEIRS IN SKIMMERS.


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 26-October-2021

Comments
Our records show that the main drain suction outlet covers (Waterway 640-472xV) were installed 4/1/2019. The covers have a 7 year life span and must be replaced before 4/1/2026. These drain covers have a maximum flow rating of 356 gpm. When replacing the covers, ensure that the new covers' flow rating will not be exceeded.