3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Public swimming pool was constructed, installed, or substantially altered without obtaining approval from the Ohio Department of Health (ODH).
Contact ODH to obtain approval for any construction/alterations before operating pool.
SUBMIT AN ERN TO ODH FOR THE REPLACEMENT OF THE DISINFECTION CHEMICAL FEEDER AND THE CIRCULATION PUMP. Correct By: 30-Jul-2020
3701-31-04 (B)(1)(f) / Lifeguards, when required, shall be on duty.
Critical Lifeguards were not on duty during the adult swim.
AT LEAST ONE LIFEGUARD MUST BE ON DUTY DURING THE ADULT SWIM. Correct By: 24-Jul-2020
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Cross connection hazards were present
Remove all cross connection hazards from the pool area.
INSTALL THE ASSE 1011 ON THE HOSE BIB LOCATED IN THE EQUIPMENT ROOM. Correct By: 30-Jul-2020
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve.
INCREASE FLOW RATE Correct By: 30-Jul-2020
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Required meters and gauges were not maintained or were not functional while the pool is in operation. One the filter pressure gauges was reading 0 psi.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation.
REPAIR THE PRESSURE GAUGE ON THE FILTER THAT IS READING 0 PSI OR REPAIR THE FILTER. Correct By: 30-Jul-2020
3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair or were not slip resistant.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.
TIGHTEN THE HANDRAIL AT THE STEPS. Correct By: 30-Jul-2020
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 24-July-2020
Comments |
---|
Keep the chemicals’ Safety Data Sheets (MSDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. The main drain suction outlet cover (Waterway 640-472xV) was installed on 5-14-19. The cover has a 7 year life span and must be replaced before 5-14-26. The cover has a flow rating of 356 gpm. |