[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat Required meters and gauges were not maintained or were not functional while the pool is in operation. Flow meter on fountain pump not functioning.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation. REPAIR/REPLACE THE FLOW METER FOR THE FOUNTAIN PUMP.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gates or doors were not self-closing and lockable. The gate of the east side (equipment room door side) does not latch.
Repair gates or doors in order to be self-closing and lockable. KEEP EAST SIDE GATE LOCKED OR REPAIR THE LATCH. Correct By: 09-Aug-2023
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. ADJUST THE ALKALINITY Correct By: 04-Aug-2023


Inspection Information


Facility Type: Special Use

[?] Inspection Type: Standard

Inspection Date: 02-August-2023