3701-31-04 (B)(1)(k) / Chemical storage or use shall not result in imminent health hazard.
Critical Repeat Different type chemicals were stacked on top of each other.
TO AVOID CHEMICAL HAZARD, STORE DIFFERENT CHEMICALS SEPARATELY AND NOT ON TOP OF EACH OTHER. Correct By: 25-May-2017
3701-31-04 (B)(6)(b) / Replacement pipe is rigid PVC or the equivalent
Repeat The rubber coupling is used to joint two lengthens of pipe.
REPLACE THE RUBBER COUPLING WITH SOLID APPROVED PIPE. Correct By: 25-Jun-2017
3701-31-04 (B)(6)(c)(v) / Discharge of water from a public swimming pool shall be in accordance with OEPA.
Repeat The backwash drain to the sewer does not have a proper air gap.
INSTALL AN AIR GAP ON THE BACKWASH DISCHARGE LINE. REPEAT VIOLATION. Correct By: 26-May-2017
3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical Repeat The SVRS has not been tested and recorded.
TEST AND RECORD THE SVRS FUNCTION AT LEAST MONTHLY. REPEAT VIOLATION Correct By: 26-May-2017
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Repeat The filter room was not locked.
TO KEEP CHEMICALS INACCESSIBLE, KEEP THE FILTER ROOM LOCKED. Correct By: 25-May-2017
3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Repeat Tri-chl is being used in the chlorinator that is labeled for calcium hypochlorite use only.
THIS IS A REPEAT VIOLATION. CHLORINE TABLETS MUST MATCH THE REQUIREMENTS OF THE EQUIPMENT. CHLORINATOR STATES THAT PPG 3" TABLETS MUST BE USED. BEGIN TO USE REQUIRED TABLETS ONLY. Correct By: 25-May-2017
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH level is below required level of between 7.2 and 7.8.
ADJUST THE pH LEVEL TO BETWEEN 7.2 AND 7.8. Correct By: 27-May-2017
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm. Correct By: 30-Jun-2017
Facility Type: Pool
[?] Inspection Type: Follow-up
Inspection Date: 26-June-2017
Comments |
---|
Progress has been made to correct violations, but not all violations have been corrected. Enforcement action will be delayed one month. HAVE ALL VIOLATIONS CORRECTED BY JULY 26 |