3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Combined chlorine was not tested daily at pool side prior to use.
-Observed the combined chlorine is not being tested for recorded.
TEST FOR COMBINED CHLORINE PRIOR TO BATHERS ENTERING THE WATER AND EVERY 4 HOURS THE POOL IS OPEN FOR USE.
.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
-Observed the alkalinity is not being tested or recorded weekly.
TEST THE TOTAL ALKALINITY AT LEAST ONCE PER WEEK.
3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Test kit reagents were not fresh.
-Observed expired reagents in the test kit.
OBTAIN FRESH REAGENTS.
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 21-July-2023
Comments |
---|
-Discussed options with cyanuric acid, as they are not currently using it. If used, the cyanuric acid must be below 70ppm. -Alkalinity should be at least 60ppm, but the ideal range is 80-120ppm. |