3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat Outlet covers were not installed.
Do not operate the pool when the outlet covers are not installed.
PLUG SKIMMER EQUALIZER OUTLET OR INSTALL VGB COVERS.
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8.
Treat the pool water so that the pH is within the acceptable range.
ADJUST pH.
ABOUT 10 OZ OF MURIATIC ACID ADDED TO YOUR POOL WILL LOWER THE pH ABOUT .2. TO LOWER THE pH .6 ADD ABOUT 30 OZ. OF MURIATIC ACID. Correct By: 11-Apr-2022
3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Test kit reagents were not fresh or stored properly.
Obtain fresh reagents and store them properly.
OBTAIN NEW TEST KIT. Correct By: 11-Apr-2022
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 08-April-2022
Comments |
---|
Keep the attached certificate of conformity for the new drain covers that were installed 3-24-22. Keep the chemicals’ Safety Data Sheets (SDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals. The operator was observed performing onsite chemical tests appropriately. See page 3-4 for proper chemical adjustment formulas. |