3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Equipment was not maintained per manufacturers specifications. Weirs weir missing in the skimmer.
All equipment must be maintained in accordance with the manufacturers specifications.
INSTALL WEIRS IN THE SKIMMERS. Correct By: 02-Jul-2021
3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Depth markers/deck warning signs were not maintained in a clearly legible/visible manner.
Replace the depth markers/deck warning signs so that bathers are able to clearly see the depth of the water and that no diving is permitted where clearly indicated.
REPAINT DEPTH MARKINGS AND "NO DIVING" SIGNS. Correct By: 02-Jul-2021
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Gates or doors were not self-closing and self-latching.
Repair gates or doors in order to be self-closing and self-latching.
ADJUST THE GATE SO IT LATCHES WHEN IT CLOSES. Correct By: 02-Jul-2021
3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Repeat Chemical containers were stored improperly. pH Up was on top of chlorine.
Properly store all chemical containers to avoid a chemical reaction or unnecessary exposure.
DO NOT STORE DIFFERENT CHEMICALS ON TOP OF EACH OTHER. Correct By: 30-Jun-2021
3701-31-04 (D)(8)(c) / Test kit reagents fresh/ properly stored.
Test kit reagents were not fresh.
Obtain fresh reagents and store them properly.
OBTAIN AND USE REAGENTS THAT ARE NOT EXPIRED. Correct By: 02-Jul-2021
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool.
Provide a 12 ft. non-telescopic reach pole in the pool area at all times.
OBTAIN AND HAVE IN PLAIN VIEW A 12' REACH POLE WITH A SHEPHERD'S CROOK. Correct By: 02-Jul-2021
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities.
MAKE AVAILABLE AN EMERGENCY PHONE. POST SIGNAGE OF THE LOCATION OF THE EMERGENCY PHONE AND POST BY PHONE "DIAL 911 IN CASE OF EMERGENCY" OR SIMILAR. Correct By: 02-Jul-2021
Facility Type: Pool
[?] Inspection Type: Standard
Inspection Date: 29-June-2021
Comments |
---|
The Certificate of Compliance for the main drain cover is available in the lifeguard room. Our records show that the main drain suction outlet covers (AquaStar WAV 12) were installed 8/7/2019. The covers have a 5 year life span and must be replaced before 8/7/2024. The operator was observed performing onsite chemical tests appropriately |