[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(d) / Circulation/Disinfection system shall operate properly.
Critical The disinfection pump is not functional
This is a critical operational item and poses an imminent health hazard. CLOSE THE POOL UNTIL THE VIOLATION IS CORRECTED. CALL THE HEALTH DEPARTMENT BEFORE OPENING TO VERIFY CORRECTIONS. POOL WAS CLOSED BY OPERATOR. Correct By: 28-Jul-2020


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 28-July-2020

Comments
When using CYA (cyanuric acid) the alkalinity level is calculated by subtracting 1/3 the CYA level from the alkalinity reading. EXAMPLE: alkalinity test reading = 70 ppm, CYA = 60 ppm. Alkalinity is 70 ppm – (60/3) = 50 ppm

Keep the chemicals’ Safety Data Sheets (MSDS) in the equipment room and have Personal Protective Equipment (PPE) such as chemical gloves and goggles available for handling chemicals.

Be careful to record combine and total chlorine correctly.