[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day. Correct By: 03-May-2022
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. INCREASE FLOW RATE TO AT LEAST 100 GPM.
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
A means of determining rate-of-flow was not found for all water pumps. Jet pump.
Properly install a flow meter or have a pump curve available for every water pump used for the pool. PLACE THE VACUUM GAUGE ON THE JET PUMP. Correct By: 09-May-2022


Inspection Information


Facility Type: Spa

[?] Inspection Type: Standard

Inspection Date: 02-May-2022

Comments
The Certificate of Compliance for the main drain cover(s) is/are available in the equipment room. Our record show that the main drain suction outlet covers (AquaStar WAV9 x 8) were installed 1/24/2020. The covers have a 5 year life span and must be replaced before 1/24/2025.