[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Information on the make and model of the drain covers was not available. The date of installation was not available.
OBTAIN THE CERTIFICATE OF COMPLIANCE AND THE INSTALLATION INSTRUCTIONS FOR THE DRAIN COVERS. ALSO OBTAIN THE DATE OF INSTALLATION. IF THE DRAIN COVERS ARE PASSED THE LIFE SPAN OR IF INFORMATION CANNOT BE OBTAINED, REPLACE THE DRAIN COVERS. Correct By: 15-Jun-2017
3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Free chlorine level is .6.
This is a critical operational item and poses an imminent health hazard. IMMEDIATELY CLOSE THE POOL UNTIL THE CHLORINE LEVEL IS 1.0 OR HIGHER AND THE HEALTH DEPARTMENT VERIFIES THE LEVEL. Call the health department at 440-219-7158. Correct By: 01-Jun-2017
3701-31-04 (B)(1)(k) / Chemical storage or use shall not result in imminent health hazard.
Critical Corrected During Inspection Liquid chemicals were stored over powdered chemicals on the shelves in the filter room. Chlorine was stored by the heater. Chlorine and acid were stored next to each other.
MOVE THE LIQUID CHEMICALS FROM ABOVE THE POWDERED CHEMICALS, SEPARATE DIFFERENT CHEMICALS, AND WHEN THE HEATER IS ON KEEP CHEMICALS AWAY FROM HEATER. Correct By: 01-Jun-2017
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Equipment was not maintained per manufacturers specifications. The skimmers are missing the weirs.
All equipment must be maintained in accordance with the manufacturers specifications. REPLACE THE WEIRS IN THE SKIMMERS. Correct By: 01-Jul-2017
3701-31-04 (B)(6)(g) / Throttle valve properly installed/maintained/adjusted
Throttle valve was not properly maintained/adjusted. The throttle valve is not tagged with the Max and min flow.
Throttle valves must be maintained in the same position was when originally installed and approved. Restore the setting of the throttle valve and lock it into place. PLACE THE MAXIMUM ALLOWABLE FLOW RATE (240 GPM) AND MINIMUM REQUIRED FLOW RATE (67 GPM) ON THE THROTTLE VALVE OR BY THE FLOW METER. Correct By: 15-Jun-2017
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
The flow meter is located 10 inches down stream from the elbow in the pipe and 10 inches up stream from the elbow in the pipe. The pipe is 3 inches in diameter.
RELOCATE THE FLOW METER SO IT IS 10 TIMES THE DIAMETER OF THE PIPE DOWN STREAM FROM AN ELBOW OR OTHER TURBULENCE AND 5 TIMES THE DIAMETER FROM THE PIPE UP STREAM FROM A TURBULENCE. Correct By: 15-Jun-2017
3701-31-04 (E)(2)(a)(iii) / A back/spine board is provided
The spine board, ring buoy with 30-60 foot rope, and the 12' reach pole with shepherd crook was not available.
PROVIDE A SPINE BOARD, RING BUOY WITH 30-60 FT ROPE, AND REACH POLE WITH SHEPHERDS CROOK. Correct By: 15-Jun-2017
3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
The unguarded pool was in use without the "Swimming alone is not recommended" signs posted.
Post the "Children must be supervised" and/or "Swimming Alone is Not Recommended" signs at all times the pool is available for use. POST THE "SWIMMING ALONE IS NOT RECOMMENDED" SIGN. Correct By: 01-Jul-2017


Inspection Information


Facility Type: Pool

[?] Inspection Type: Standard

Inspection Date: 01-June-2017